Effect Circulator Pump

Effect Circulator PumpThis Circulator Pump is used within a Chemical Plant.

This First Effect pump’s premature wear in a caustic solution caused frequent overhauls and expensive repairs in excess of $135,000 per year.

We updated the material and used a new 2906 Stainless Steel material. We then modified the bearing overhung load to support impeller internally in the pump which also allowed the use of a mechanical seal.

Utilization of a mechanical seal significantly reduced water consumption. Performance has exceeded expectations and offered a return on investment within 6 months.